TECHNICAL GUIDE
SINGLE PIECE STANDARD ECM
AIR HANDLERS
FOR USE WITH SPLIT-SYSTEM
COOLING & HEAT PUMPS
MODELS: AHE18 THRU 60*
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at:
www.york.com
Additional rating information can be found at:
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replace-
ment or closing for new home construction.
ISO 9001
Certified Quality
Management System
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
680210-YTG-B-0311
DESCRIPTION
The Air Handler line offers the ultimate in comfort, sound and
application flexibility. The air handler is shipped ready to be
installed in upflow, horizontal left or right position, with minor
adjustments. No special kits are required to install this deluxe
product.
All JCI Unitary Products air handlers and coils use a TXV to pro-
vide our customers with the optimum performance and refriger-
ant control. Air handlers are shipped with “Flex-coils” without a
factory installed metering device. For added flexibility, an R-22
or R-410A TXV or orifice can be field installed to meet your
refrigerant choice.
FEATURE
Thermal Expansion Valve - Provides the ultimate refrigerant
control required for today’s high efficient product. The UPG bolt-
on TXV provides easy installation to convert the air handler to
the required refrigerant, which is a true bolt-on design that does
not require brazing to replace or install.
Insulated Cabinet - All air handler cabinets are thermally insu-
lated with 3/4” foil faced insulation to prevent sweating.
Factory Sealed - Achieves 2% or less total airflow leakage rate
at duct blaster field test conditions for system airflow verifica-
tion.
Durable Finish Inside and Out - Air handler casings are made
of pre-painted galvanized steel which provides a better paint to
steel bond that resists corrosion and rust creep. All internal coil
sheet metal parts are made of G60 galvanized or prepainted
G30 galvanized.
Filters - All models have internal filter racks provided for use
with 1” thick standard size filters.
Electric Heat Kits - New 6HK series of field installed electric
heat kits are available for installation friendly and easy service
applications. These 6HK kits are unique to these new models.
High Efficiency Blowers - All models use high efficiency
brushless DC motors to provide cooling SEER rating enhance-
ment.
Vista de página 0
1 2 3 4 5 6 ... 13 14

Resumo do Conteúdo

Página 1 - TECHNICAL GUIDE

TECHNICAL GUIDESINGLE PIECE STANDARD ECMAIR HANDLERSFOR USE WITH SPLIT-SYSTEMCOOLING & HEAT PUMPSMODELS: AHE18 THRU 60*Due to continuous product i

Página 2 - COIL TECHNICAL DATA

10 Johnson Controls Unitary Products680210-YTG-B-0311TYPICAL THERMOSTAT CONNECTION

Página 3 - COOLING CAPACITY

Johnson Controls Unitary Products 11680210-YTG-B-0311TYPICAL THERMOSTAT WIRING FOR 2-STAGE HEAT PUMP WITH ECM BLOWER MOTOR

Página 4 - COOLING CAPACITY (Continued)

12 Johnson Controls Unitary Products680210-YTG-B-0311AIR FLOWAIR FLOW DATA - 60 Hz MODELS - 208 VOLTModelsBlower Motor SpeedCFM1 @ External Static Pre

Página 5 - 1. Field Supplied

Johnson Controls Unitary Products 13680210-YTG-B-0311AIR FLOW DATA - 60 Hz MODELS - 230 VOLTModelsBlower Motor SpeedCFM1 @ External Static Pressure -

Página 6

Subject to change without notice. Published in U.S.A. 680210-YTG-B-0311Copyright © 2011 by Johnson Controls, Inc. All rights reserved. Supersedes: 680

Página 7

2 Johnson Controls Unitary Products680210-YTG-B-0311DIMENSIONS & DUCT CONNECTION DIMENSIONSJDBlowerCompartmentCircuit BreakerPanelDrain Pan Connec

Página 8

Johnson Controls Unitary Products 3680210-YTG-B-0311COOLING CAPACITYModels Rated CFMEntering Air °F (Dry/Wet Bulb)MBH@ Evaporator Temperature and Corr

Página 9 - LIMITATIONS

4 Johnson Controls Unitary Products680210-YTG-B-0311Note: Airflow is calculated for each system tonnage. Capacity varies with O.D. product.AHE42D3XH21

Página 10 - TYPICAL THERMOSTAT CONNECTION

Johnson Controls Unitary Products 5680210-YTG-B-0311APPLICATION FACTORS - RATED CFM VS. ACTUAL CFM% Of Rated Airflow (CFM)80% 90% 100% 110% 120%Capaci

Página 11 - 680210-YTG-B-0311

6 Johnson Controls Unitary Products680210-YTG-B-0311ELECTRICAL DATA - 208/230-1-60ModelsHeater Models*Max. StaticECM Min. Speed TapTotal Heat1kW Stagi

Página 12 - AIR FLOW

Johnson Controls Unitary Products 7680210-YTG-B-0311ELECTRICAL DATA - (FOR SINGLE SOURCE POWER SUPPLY) - COPPER WIRE - 208/230-1-60ModelsHeater Models

Página 13

8 Johnson Controls Unitary Products680210-YTG-B-0311ELECTRICAL DATA - (FOR MULTI-SOURCE POWER SUPPLY) - COPPER WIRE - 208/230-1-601ModelsHeaterModelsM

Página 14 - Norman, OK 73069

Johnson Controls Unitary Products 9680210-YTG-B-03112. Heaters are 3 Phase.TYPICAL APPLICATIONSACCESSORIESRefer to Price Manual for specific model num

Comentários a estes Manuais