GENERAL
YORK Model DEE units are single package air conditioners
designed for outdoor installation on a rooftop or a slab. Electric
heaters are available as field-installed accessories.
The units are completely assembled on rigid, permanently
attached base rails. All piping, refrigerant charge, and electrical
wiring is factory-installed and tested. The units require only
electric power and duct connections at the point of installation.
The electric heaters have nickel-chrome elements and utilize
single point power connection.
INSPECTION
As soon as a unit is received, it should be inspected for possible
damage during transit. If damage is evident, the extent of the
damage should be noted on the carrier's freight bill. A separate
request for inspection by the carrier's agent should be made in
writing. Refer to Form 50.15-NM for additional information.
REFERENCE
Additional information on the design, installation, operation and
service of this equipment is available in the following reference
forms:
55.70-N1 -General Installation
55.70-N2 -Pre-start & Post-start Check List
530.18-N1.2V -Economizer Accessory
530.18-N1.13V -Man. Outdoor Air Damper Accy 0-35%
530.18-N1.14V -Man. Outdoor Air Damper Accy 0-100%
530.18-N1.12V -Motorized Outdoor Air Damper Accy.
530.18-N1.8V -Coil Guard
530.18-N7.1V -Electric Heater Accessory
530.18-N7.2V -Fuse Block Accessory
690.15-N25V -Low Ambient to 0°F
Renewal Parts:
Refer to Parts Manual for complete listing of replacement
parts on this equipment.
All forms referenced in this instruction may be ordered from:
Standard Register
Toll Free Tel: 877-318-9675/Fax. 877-379-7920
APPROVALS
Design certified by U.L. and C.G.A. as follows:
1. For use as a cooling only unit or cooling unit with electric heat.
2. For outdoor installation only.
3. For installation on combustible material.
®
SUNLINE 2000
ELECTRIC / ELECTRIC
SINGLE PACKAGE AIR CONDITIONERS
INSTALLATION INSTRUCTION
Supersedes: 035-12046-002-A-0302
035-12046-003-A-0204
Installer should pay particular attention to the words: NOTE, CAUTION and WARNING. Notes
are intended to clarify or
make the installation easier. Cautions
are given to prevent equipment damage. Warnings are given to alert installer that per
-
sonal injury and/or equipment damage may result if installation procedure is not handled properly.
MODELS D1EE 048 & 060
and D2EE 036 (11 SEER)
CAUTION
THE ENCLOSED INSTALLATION INSTRUCTIONS AND ANY APPLICABLE
LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED
TO, BUILDING, ELECTRICAL, AND MECHANICAL CODES.
THIS PRO DUC T M UST BE INSTALLED IN STRICT COMPLIANCE W ITH
WARNING
OPERATION OF THE PRODUCT COULD CAUSE PERSONAL INJURY
OR PROPERTY DAMAGE.
INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - INSTALLATION INSTRUCTION

GENERALYORK Model DEE units are single package air conditionersdesigned for outdoor installation on a rooftop or a slab. Electricheaters are available

Página 2 - TABLE OF CONTENTS

035-12046-003-A-020410 Unitary Products GroupTABLE 5 - SUPPLY AIR PERFORMANCE - 5 TON w/Belt-Drive BlowerUNITSIZE(MBH)AIR FLOWCFMAvailable External St

Página 3 - INSTALLATION

035-12046-003-A-0204Unitary Products Group 11EXTERNAL STATIC PRESSURE DROPDESCRIPTIONRESISTANCE, IWGCFM1000 1200 1400 1600 1800 2000 2200 2400 2600 28

Página 4 - (SEE NOTE)

The heaters are wired for a single point power supply. Powersupply need only be brought into the single point terminal blockand thermostat wiring to t

Página 5 - OPTIONAL ECONOMIZER RAIN HOOD

HEAT ANTICIPATOR SETPOINTSIt is important that the anticipator setpoint be correct. Too highof a setting will result in longer heat cycles and a great

Página 6 - S I N G L E S T A G E

035-12046-003-A-020414 Unitary Products GroupSECURE OWNER'S APPROVAL: When the system is functioning properly, secure the owner's approval.

Página 7 - UTILITIES ENTRY DATA

035-12046-003-A-0204Unitary Products Group 15

Página 8

Unitary Products Group5005 York Drive, Norman, Oklahoma 73069Subject to change without notice. Printed in U.S.A 035-12046-003-A-0204Copyright © 2004

Página 9

035-12046-003-A-02042 Unitary Products GroupGeneral...1Inspection...

Página 10 - - Side Duct Connections

LIMITATIONSThese units must be installed in accordance with the currentedition of the following national and local safety codes:In USA:1. National Ele

Página 11 - (SEE NOTE 2)

kept clean or replaced with same size and type. Dirty filters willreduce the capacity of the unit and will result in frosted coils orsafety shutdown.

Página 12 - OPERATION

All direct-drive units with 460 and 575 voltage are shipped withthe wire labeled #116 connected to the “HIGH” speed tap onthe blower motor. If the med

Página 13 - PRESSURE DROP (IWG)

10. To check that the damper blades move smoothly withoutbinding, carefully turn the minimum position adjustingscrew fully clockwise and then energize

Página 14 - MAINTENANCE

035-12046-003-A-0204Unitary Products Group 7FIG. 5 - DIMENSIONS & CLEARANCES - 3 - 5 TONSDUCT COVERS - Units are shipped with all air ductopenings

Página 15 - Unitary Products Group 15

Install the bracket on the left hand side of the unit as shown inFigure 5. Several existing screws at the top of the unit and onescrew approximately m

Página 16 - Unitary Products Group

035-12046-003-A-0204Unitary Products Group 9TABLE 4 - SUPPLY AIR PERFORMANCE - 3 & 4 TON w/Belt-Drive BlowerUNITSIZE(MBH)AIR FLOWCFMAvailable Exte